FAQ

Accessories

Make sure you have all connectors and tubing needed for packing and running the column.

Depending on your system configuration and column length, you may need extra long tubing to connect your column.

2x Fingertight connector 1/16" Male, 2x Union 1/16" female-1/16" female and 2x Fingertight stop plug 1/16" are supplied with the column.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 PEEK Tubing, 2 m, i.d. 1.0 mm, o.d. 1/16" 18111583 85.34 USD Add to cart
2 Fingertight Connector 1/16" Male 18117263 83.91 USD Add to cart
3 Union 1/16" female-1/16" female 11000339 170.07 USD Add to cart
4 Fingertight Stop Plug, 1/16'' 11000355 79.16 USD Add to cart
Tubing cutter, for PEEK, EFTE, and FEP tubing i.d. 0.25, 0.5, 0.75, 1 and 1.6 mm 18111246 99.55 USD Add to cart
Column Holder 28956282 138.69 USD Add to cart
Column Clamp 28956319 83.84 USD Add to cart
Accessory kit for HiScale 16 columns 28966367 108.65 USD Add to cart

 

Make sure you have all connectors and tubing needed for packing and running the column.

Depending on your system configuration and column length, you may need extra long tubing to connect your column.

2x Fingertight stop plug 1/16", 2x Union 1/16" female-1/16" female and 2x Fingertight connector 1/16" male are supplied with the column.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 PEEK Tubing, 2 m, i.d. 1.0 mm, o.d. 1/16" 18111583 85.34 USD Add to cart
2 Fingertight Connector 1/16" Male 18117263 83.91 USD Add to cart
3 Union 1/16" female-1/16" female 11000339 170.07 USD Add to cart
5 Fingertight Stop Plug, 1/16'' 11000355 79.16 USD Add to cart
6 Column tube assembly 28966646 669.32 USD Add to cart
6 Column tube assembly 28966652 868.18 USD Add to cart
Tubing cutter, for PEEK, EFTE, and FEP tubing i.d. 0.25, 0.5, 0.75, 1 and 1.6 mm 18111246 99.55 USD Add to cart
Short column holder, for columns 10 to 50 mm o.d. 18111317 220.00 USD Add to cart
Column Holder 28956282 138.69 USD Add to cart
Column Clamp 28956319 83.84 USD Add to cart
Spanner wrench 28964776 109.68 USD Add to cart
Accessory kit for HiScale 16 columns 28966367 108.65 USD Add to cart
O-ring packing connector 28966653 76.88 USD Add to cart
Packing tube 40 for HiScale 16 columns 28986815 1,252.55 USD Add to cart
Packing tube 20 HiScale 16 28986816 972.72 USD Add to cart

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Spanner wrench 28964776 109.68 USD Add to cart
3 Short column holder, for columns 10 to 50 mm o.d. 18111317 220.00 USD Add to cart
4 Superloop, 1/16" fittings, 10 ml 18111381 1,173.00 USD Add to cart
5 Superloop, 1/16" fittings (ÄKTAdesign), 50 ml 18111382 1,362.00 USD Add to cart
6 Superloop Complete, 150 ml, M6 fitting 18102385 1,701.00 USD Add to cart
7 Fingertight Union 1/16" Male/M6 Female 18111258 135.19 USD Add to cart
8 Connector 1/16" Male/Luer Female 18111251 109.24 USD Add to cart
9 Net for Columns, i.d 16 mm, 10 µm 18876101 76.88 USD Add to cart
10 PEEK Tubing, 2 m, i.d. 1.0 mm, o.d. 1/16" 18111583 85.34 USD Add to cart
11 Tubing cutter, for PEEK, EFTE, and FEP tubing i.d. 0.25, 0.5, 0.75, 1 and 1.6 mm 18111246 99.55 USD Add to cart
13 O-ring packing connector 28966653 76.88 USD Add to cart
14 Column tube assembly 28966646 669.32 USD Add to cart
15 Column tube assembly 28966652 868.18 USD Add to cart
16 Column Holder 28956282 138.69 USD Add to cart
17 Column Clamp 28956319 83.84 USD Add to cart
18 Accessory kit for HiScale 16 columns 28966367 108.65 USD Add to cart

Spare parts

Figure. HiScale 16 column.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 Adapter complete for HiScale 16 28966383 507.37 USD Add to cart
8 Column tube assembly 28966646 669.32 USD Add to cart
8 Column tube assembly 28966652 868.18 USD Add to cart
9 Fingertight Stop Plug, 1/16'' 11000355 79.16 USD Add to cart
10 Union 1/16" female-1/16" female 11000339 170.07 USD Add to cart
12 Connector for 1/16 tubing 29018382 70.72 USD Add to cart
20 Ferrules for o.d. 1/16" tubing connector 18112706 159.39 USD Add to cart
23 O-Ring, 10.3 × 2.4 mm 19016301 60.47 USD Add to cart
25 Support Screen for Column, i.d. 16 mm 19065101 52.28 USD Add to cart
26 Net ring 20 µm 28966379 98.40 USD Add to cart

O-rings and nets should be checked regularly for wear. Worn O-rings may not seal properly and over-used nets can affect distribution. Inspect the O-rings and evaluate the height equivalent to a theoretical plate (HETP) and peak asymmetry factor (As) to prevent poor performance due to old nets. 

We recommend you to change the nets and O-rings when needed or at least annually. Please keep a set of each on your site, the code numbers refer to the table below.

Something went wrong - we were not able to load your agreed MSA pricing. Please try refreshing the page.
# Product Name Product Code Price
1 PEEK Tubing, 2 m, i.d. 1.0 mm, o.d. 1/16" 18111583 85.34 USD Add to cart
2 Support Screen for Column, i.d. 16 mm 19065101 52.28 USD Add to cart
3 O-Ring, 10.3 × 2.4 mm 19016301 60.47 USD Add to cart
4 Net ring 20 µm 28966379 98.40 USD Add to cart
5 Spanner wrench 28964776 109.68 USD Add to cart
6 Ferrules for o.d. 1/16" tubing connector 18112706 159.39 USD Add to cart
7 Accessory kit for HiScale 16 columns 28966367 108.65 USD Add to cart
8 Tubing cutter, for PEEK, EFTE, and FEP tubing i.d. 0.25, 0.5, 0.75, 1 and 1.6 mm 18111246 99.55 USD Add to cart

Troubleshooting

Find solutions to product related issues. For unlisted issues please contact local Cytiva service representation.

Poor product recovery

Select the description that fits with your symptom

Worrying peak shape

Select the description that fits with your symptom

Drifting baseline

Select the description that fits with your symptom

Poor reproducibility

Select the description that fits with your symptom

Poor packing evaluation result

On this troubleshooting site, we refer to leading and tailing peaks as defined according to the following figures.
 
 

Leading peak Tailing peak

 
Experience shows that the best method of expressing the efficiency of a packed column is in terms of its height equivalent to a theoretical plate (HETP), reduced plate number (h) and its peak asymmetry factor (As). 

Please be aware of that for small columns, less than 10 ml bed volume, the system dead volume has an impact on the column evaluation values.

Issues related to Poor packing evaluation result

General advice to achieve good performance

Before using the system make sure that:

  • The correct system has been selected in UNICORN System Control
  • The correct wavelength has been set for UV/UPC monitor
  • All tubing has been properly connected
  • All connectors are free from leakage
  • No tubing is folded or twisted
  • Online filter, if used, is changed on a regular basis
  • Correct buffers are used for the chosen columns and proteins
  • All inlet tubing has been immersed in correct buffer solutions
  • Enough buffer has been prepared
  • Buffers have been equilibrated to the environment temperature
  • Buffers/eluents have been degassed if necessary (e.g., in RPC runs)
  • Suitable columns have been selected for the target proteins
  • Columns have been cleaned and prepared according to column instructions
  • Samples have been clarified by centrifugation and/or filtration prior to sample loading
  • Samples have been adjusted to binding buffer conditions
  • Auto sampler (if used) has been prepared according to user manual
  • The fraction collector has been filled with appropriate number of microtiter plates or tubes
  • Appropriate arrangement for waste handling has been prepared

Column leakage

Select the description that fits with your symptom

Unsatisfactory elution

Select the description that fits with your symptom

Back pressure increases during operation

Unusual column appearance

Select the description that fits with your symptom

Strange peaks

Select the description that fits with your symptom